EN50288-7 RE-2X(st)H SWAH Instrumentation Kabel
Dirigent: Bare Annealed Copper
Isolaasje: XLPE (Cross-Linked Polyethylene)
Algemiene skerm: Al / PET (Aluminium / Polyester Tape)
Drain Wire: Tinned Koper
Binnenskede: LSZH (Low Smoke Zero Halogen)
Armour: SWA (Galvanized steel wires)
Outer sheath: LSZH (Low Smoke Zero Halogen)
Rated Voltage: 500V
Rated temperatuer: -20 ~ + 70 ℃
NEE. FAN | NOMINAL CROS SECTIONAL AREA | NOMINALE OVERALL DIAMETER |
1 P | 0.5 | 9 |
1 P | 0,75 | 9.5 |
1 P | 1 | 9.4 |
1 P | 1.5 | 10.8 |
1T | 0.5 | 9.2 |
1T | 0,75 | 9.8 |
1T | 1 | 9.7 |
1T | 1.5 | 11.3 |
2P(Q) | 0.5 | 11.2 |
2P(Q) | 0,75 | 12.2 |
2P(Q) | 1 | 12 |
2P(Q) | 1.5 | 14.4 |
5P | 0.5 | 13.1 |
5P | 0,75 | 14.4 |
5P | 1 | 14.2 |
5P | 1.5 | 17.4 |
10P | 0.5 | 16.7 |
10P | 0,75 | 18.6 |
10P | 1 | 18.2 |
10P | 1.5 | 23.7 |
15P | 0.5 | 11.3 |
15P | 0,75 | 21.5 |
15P | 1 | ienentweintich |
15P | 1.5 | 27.5 |
20P | 0.5 | 21.1 |
20P | 0,75 | 23.7 |
20P | 1 | 23.1 |
20P | 1.5 | 30.4 |
2X stiet foar XLPE isolaasje H betsjut Halogen frij sawol yn binnenste jas en bûtenste jas, SWA galvanized stielen tried Armor, ST betsjut kollektyf skerm meastal kinne wy begripe as AL / pet tape plus drain wire.
Applikaasje en beskriuwing
Instrumentaasjekabels neffens BS EN 50288-7 wurde brûkt foar de oerdracht fan analoge en digitale sinjalen yn ynstrumintaasjekontrôlesystemen en binne klassifisearre neffens IEC 79-14 foar gebrûk yn groep II, Zones 1 en 2 omjouwings, en binne net te ferbinen direkt nei lege impedans Netzteil, bygelyks iepenbiere macht oanbod stasjons.
Oanrikkemandearre foar ynstallaasjes binnen en bûten, beugels, trays, pipelines, wiete en droege omjouwings, net oan te rieden foar direkte begraffenis.
Oanrikkemandearre foar gebrûk yn brânbeskermingsmaatregels foar libbens- en fitale eigendommaterialen.
Fire Resistance Skaaimerken
Flammefertragende eigenskippen (fertikale flammetest mei ien kabel) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (kat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1 *; din vde 0482-265-2-1*
Rated Voltage
300/500V
Kabelkonstruksje
Conductor IEC 60228 Type 2 multi-string annealed koperen dirigint.
Isolaasje Extruded XLPE gearstalde isolaasje neffens EN 50290-2-29.
Pairing 2 isolearre kearnen wurde ferdraaid tegearre te foarmjen in pear.
Twisted Pairs fan kabels wurde twisted yn lagen mei optimale ôfstân.
Wrapping tape PETP tape
Algemiene shielding Aluminium/polyester tape laach shield mei 0,5 mm² tin koper drain tried.
Binnenskede LSZH-ferbining neffens EN 50290-2-27.
Armouring Galvanized stielen tried armouring.
Outer sheath EN 50290-2-27 standert LSZH compound. UV, koalwetterstof, oalje, knaagdieren en termite-resistinte eigenskippen binne opsjoneel.
Kleur
Isolaasje: swart / wyt, kabelpearen wurde efterinoar identifisearre mei sifers (1, 2,,,) op wite kearnen.
Skede: swart of blau (yntrinsyk feilige systemen)
Fysyke eigenskippen
Operating temperatuer berik (stasjonêre steat) -30 ° C - +90 ° C
Ynstallaasje temperatuer berik (yn beweging) -5 ° C - +50 ° C
Minimale bochtradius 10 X bûtendiameter
UV-resistint UL 1581 seksje 1200
Oalje Resistant
ICEA S-73-532 (Test by +60 ° C foar 4 oeren. Minimum treksterkte en elongation fan 60% wurdt hanthavene oer de 4 oere perioade).